Heart rate response and clinical determinants of Glittre activities of daily living test performance in pediatrics with cystic fibrosis


Creative Commons License

BOZDEMİR C., Kocaaga E., Tekerlek H., İNAL İNCE D., ARIKAN H., SAĞLAM M., ...Daha Fazla

Scientific Reports, cilt.16, sa.1, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 16 Sayı: 1
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1038/s41598-026-74157-4
  • Dergi Adı: Scientific Reports
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, EMBASE, MEDLINE, Directory of Open Access Journals, Zoological Record, Academic Search Ultimate (EBSCO), Natural Science Collection (ProQuest), Biological Science Database (ProQuest), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
  • Anahtar Kelimeler: Activities of daily living, Cystic fibrosis, Energy expenditure, Pediatrics, Walk test
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Hacettepe Üniversitesi Adresli: Evet

Özet

The Pediatric Glittre Activities of Daily Living Test (TGlittre-P) is a field test designed to assess the functional performance of activities of daily living (ADL) in pediatric patients with cystic fibrosis (CF). However, the effects of TGlittre-P on heart rate response and the clinical determinants of test performance in this population remain insufficiently understood. To compare the heart rate response elicited by the TGlittre-P and the six-minute walk test (6MWT), and to identify pulmonary and extrapulmonary factors associated with TGlittre-P performance in pediatric patients with CF. Fifty-four pediatric patients with CF (mean age = 14.46 ± 2.16 years, 31 females and 23 males) were included in this cross-sectional study. ADL performance was assessed using the TGlittre-P, and functional capacity was assessed using the 6MWT. Pulmonary function, including forced expiratory volume in one second (FEV₁) and forced vital capacity (FVC), maximal inspiratory and expiratory pressure (MIP and MEP, respectively), handgrip strength (HGS %) and quadriceps muscle strength (QMS %) were measured. A multiple linear regression analysis model was used to determine independent predictors of TGlittre-P performance. The mean TGlittre-P duration was 2.00 ± 0.53 min. There was agreement between recorded peak heart rate (HRpeak) responses during the TGlittre-P and 6MWT (mean difference: -2.33%, with limits of agreement ranging from − 41.19 to 36.52). HRpeak (bpm), HRpeak (% predicted HRmax), and pre-to-post changes in systolic and diastolic blood pressure (mmHg), oxygen saturation (%), and perceived effort were not different between TGlittre-P and 6MWT (p > 0.05). TGlittre-P duration (min) correlated with 6MWT distance (m), FEV1 (%), FEV1z-score, FVC (%), FVC z-score, MIP (cmH2O), MEP (cmH2O), HGS (%) and QMS (%) (p < 0.05). The FEV1 z-score, height z-score and sex were predictors for TGlittre-P duration (min) [Adjusted R2 = 0.402, F(3, 53) = 11.755, p < 0.001, constant = 1.625]. No significant differences were observed in the measured heart rate response between the TGlittre-P and 6MWT. TGlittre-P performance is strongly associated with pulmonary function and respiratory and peripheral muscle strength. Airway obstruction was the strongest predictor of TGlittre-P performance in this population.