Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation


Ricci V., Mezian K., Chang K., Tamborrini G., Jačisko J., Naňka O., ...Daha Fazla

Foot and Ankle Surgery, 2024 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Basım Tarihi: 2024
  • Doi Numarası: 10.1016/j.fas.2024.01.005
  • Dergi Adı: Foot and Ankle Surgery
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, EMBASE, MEDLINE
  • Anahtar Kelimeler: Ankle, Intervention, Paratenonitis, Sonography, Tendinopathy
  • Hacettepe Üniversitesi Adresli: Evet

Özet

Background: Injections around the Achilles tendon (AT) are commonly performed in clinical practice to manage non-insertional Achilles tendinopathy, but the presence/distribution of the injectate with relation to its sheath has not been assessed specifically. Accordingly, the aim of this cadaveric investigation was to demonstrate the feasibility of Achilles paratenon injection under ultrasound guidance - by confirming the exact needle positioning as well as the dye distribution inside the paratenon lumen. Methods: A descriptive laboratory study with three human cadaveric specimens (one fresh cadaver and two cadavers embalmed using the Fix for Life (F4L) method) was performed in a tertiary-care academic institution. The interventional technique and the related anatomical findings were illustrated. During the injection, the needle was advanced inside the Achilles paratenon under ultrasound guidance i.e. in-plane medial-to-lateral approach. With the objective to confirm its correct placement, the needle was kept in situ on the right AT of the fresh cadaver. Likewise, to demonstrate the location of the dye inside the lumen of Achilles paratenon, the other five ATs - four on the embalmed cadavers and one on the fresh cadaver - were injected with 5 mL of green color dye. After removal of the needle, a layer-by-layer anatomical dissection was performed on all three cadavers. Results: On the right AT of the fresh cadaver, the position of the needle's tip within the Achilles paratenon was confirmed. Accurate placement of the dye inside the paratenon lumen was confirmed in four (80%) ATs, one of the fresh and three of the embalmed cadavers. No spread inside the crural fascia compartment or between the AT and the Kager's fat pad was observed. Herewith, unintentional spilling of the dye within the superficial soft tissues of the posterior leg was reported in the left AT of one of the two embalmed cadavers (20%). Conclusions: Ultrasound-guided injection using the in-plane, medial-to-lateral approach can accurately target the lumen of Achilles paratenon.