Zero-Contrast Percutaneous Left Atrial Appendage Closure in High-Risk Patients With Mitral Valve Prosthesis: Feasibility, Safety, and Midterm Outcomes


DOĞAN M., ATEŞ A. H., CANPOLAT U., KIVRAK A., KARAKULAK U. N., ÇÖTELİ C., ...Daha Fazla

Journal of Interventional Cardiology, cilt.2026, sa.1, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 2026 Sayı: 1
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1155/joic/5323969
  • Dergi Adı: Journal of Interventional Cardiology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, Directory of Open Access Journals, Academic Search Ultimate (EBSCO), Biomedical Reference Collection: Corporate Edition (EBSCO), Health Research Premium Collection (ProQuest)
  • Anahtar Kelimeler: atrial fibrillation, left atrial appendage closure, mitral valve replacement, zero-contrast technique
  • Hacettepe Üniversitesi Adresli: Evet

Özet

Background: Patients with mechanical or bioprosthetic mitral valve replacement (MVR) face a persistently high risk for thromboembolic events, even with optimal oral anticoagulation (OAC). Percutaneous left atrial appendage closure (LAAC) offers an alternative, yet evidence in this complex, high-risk population remains limited. Objectives: This study aimed to assess the immediate and midterm feasibility and safety of percutaneous zero-contrast LAAC in patients with prior MVR and persistent high thromboembolic/bleeding risk. Methods: This single-center retrospective study included 18 high-risk patients (12 mechanical, 6 bioprosthetic MVR) who underwent zero-contrast LAAC between January 2015 and May 2025. Indications included OAC-refractory LAA thrombus (n = 9), major bleeding (n = 4), recurrent stroke (n = 2), surgical residual leak closure (n = 2), and LAA electrical isolation (n = 1). All LAAC procedures were performed under combined transesophageal echocardiographic and fluoroscopic guidance without iodinated contrast administration; in two patients, contrast was used exclusively for a concomitant transcatheter valve intervention. Results: All procedures were successful without major periprocedural complications. During a median follow-up of 15.0 months (range 3–60), five patients (27.8%) died and one (5.6%) experienced major gastrointestinal bleeding. Crucially, no patient experienced ischemic stroke, clinically detected device-related thrombus, or device embolization. Cumulative event-free survival rates were 94% at 3 months and 74% at 12 months. Conclusions: Percutaneous zero-contrast LAAC was technically feasible and was associated with favorable procedural safety in this small, selected cohort of high-risk patients with prior MVR. No thromboembolic events were observed during follow-up; however, given the small single-arm cohort and the substantial competing mortality, these findings should primarily be interpreted as evidence of procedural feasibility and short-term procedural safety rather than durable thromboembolic protection.