Peptide nanotubes/self-assembled polydopamine molecularly imprinted biochip for the impedimetric detection of human Interleukin-6


YAMAN Y. T., AKBAL VURAL Ö., BOLAT G., ABACI S.

BIOELECTROCHEMISTRY, cilt.145, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 145
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1016/j.bioelechem.2022.108053
  • Dergi Adı: BIOELECTROCHEMISTRY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, Biotechnology Research Abstracts, CAB Abstracts, Chemical Abstracts Core, Chimica, Compendex, EMBASE, MEDLINE, Veterinary Science Database
  • Anahtar Kelimeler: Interleukin-6, Molecularly imprinted, Polydopamine, Peptide nanotube, Impedimetric detection, SENSITIVE ELECTROCHEMICAL DETECTION, LABEL-FREE, MODIFIED ELECTRODES, CARBON ELECTRODE, FACILE SYNTHESIS, GRAPHENE OXIDE, NANOPARTICLES, APTASENSOR, IMMUNOSENSOR, POLYMER
  • Hacettepe Üniversitesi Adresli: Evet

Özet

In the study, an impedimetric biochip was designed with molecularly imprinted polydopamine (MIP (pDa)) on peptide nanotube (PNT) functionalized screen printed electrodes (SPEs) and adopted first time as a support matrix to construct the electrochemical sensor for the determination of interleukin 6 (IL-6). IL-6, which is one of the important cytokines, was used as a template molecule during the self-assembly polymerization strategy of dopamine. Dopamine acted as a functional monomer and self-polymerization occurred without any initiator, enzyme, or crosslinker. Impedimetric, spectrometric, and morphological characterization data demonstrated that MIP(pDa)/PNT provided satisfactory performance for the impedimetric diagnosis of IL-6. Analyzed IL-6 biomolecules could be detected in the range of 1- 200 pg/mL due to the good correlation between the redox pair response and the logarithm of IL-6 con-centration. The MIP(pDa)/PNT electrode was capable of selective binding for IL-6 with high recovery val-ues in urine sample. The designed methodology allowed us to detect IL-6 with an effective, facile and inexpensive route that was easy to fabricate and scale-up. The coupling of MIP(pDa)/PNT with SPEs and the use of the impedimetric detection approach holds great potential to provide a new avenue for clinical diagnostics because in these systems small volumes of samples can be analyzed without the need for any pre-processing steps in short times.(c) 2022 Elsevier B.V. All rights reserved.