Usefulness of 'figure-of-eight' suture to achieve haemostasis after removal of 15-French calibre femoral venous sheath in patients undergoing cryoablation


Creative Commons License

AYTEMİR K., CANPOLAT U., YORGUN H., EVRANOS B., KAYA E. B., ŞAHİNER M. L., ...Daha Fazla

EUROPACE, cilt.18, sa.10, ss.1545-1550, 2016 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 18 Sayı: 10
  • Basım Tarihi: 2016
  • Doi Numarası: 10.1093/europace/euv375
  • Dergi Adı: EUROPACE
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.1545-1550
  • Anahtar Kelimeler: Atrial fibrillation, Cryoablation, Femoral vein haemostasis, PULMONARY VEIN ISOLATION, ATRIAL-FIBRILLATION, TRANSCATHETER PROCEDURES, CARDIAC-CATHETERIZATION, CLOSURE DEVICE, ABLATION, ACCESS, SAFETY, CRYOBALLOON, MANAGEMENT
  • Hacettepe Üniversitesi Adresli: Evet

Özet

Among patients undergoing cryoballoon-based atrial fibrillation (AF) ablation, in order to reduce access site complications, improve staff efinot signciency, and decrease length of stay, various techniques have been implemented to achieve immediate haemostasis. We aimed to assess the efficacy and safety of 'figure-of-eight (FoE)' suture when compared with conventional manual compression for immediate closure of 15-French (Fr) calibre right femoral venous access after cryoablation.