Effect of sintering time on the marginal and internal fit of monolithic zirconia crowns containing 3-4 mol% Y2O3


Creative Commons License

Ozden Y. E., GÜNCÜ M. B., AKTAŞ G., Canay S.

BMC ORAL HEALTH, cilt.22, sa.1, 2022 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 22 Sayı: 1
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1186/s12903-022-02563-x
  • Dergi Adı: BMC ORAL HEALTH
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CAB Abstracts, CINAHL, EMBASE, MEDLINE, Directory of Open Access Journals
  • Anahtar Kelimeler: Monolithic, Zirconia, Sintering, Marginal, Fit, FLEXURAL STRENGTH, CEMENT SPACE, GRAIN-SIZE, FRACTURE, TEMPERATURE
  • Hacettepe Üniversitesi Adresli: Evet

Özet

Background Short-term sintering may offer advantages including saving time and energy but there is limited evidence on the effect that altering sintering time has on the accuracy of monolithic zirconia crowns. The purpose of this in vitro study was to investigate the effect of shortened sintering time on the marginal and internal fit of 3Y-TZP and 4Y-TZP monolithic crowns. Methods Sixty monolithic zirconia crowns were fabricated for the maxillary first molar tooth on the prefabricated implant abutment. Groups were created according to the material composition: 3Y-TZP Generation 1, 3Y-TZP Generation 2 and 4Y-TZP. Two different sintering protocols were performed: same final sintering temperature (1500 degrees C) and various rates of heating (10 degrees C/min and 40 degrees C/min), cooling down speed (- 10 degrees C/min and - 40 degrees C/min), holding time (45 and 120 minutes), and total sintering time (approximately 2 and 7 hours, respectively). The marginal and internal fit of the crowns were determined using the silicone replica technique. Comparisons between groups were analyzed using two-way ANOVA. Pairwise multiple comparisons were performed using t-test (p < 0.05). Results The mean marginal gap values of 4Y-TZP zirconia revealed statistically significant increase for the short-term sintering protocol (p < 0.0001), while no difference was observed between the sintering protocols for the mean marginal gap values of 3Y-TZP groups. Although all groups showed clinically acceptable gap values, altering the sintering time had an effect on marginal fit of the crowns manufactured from 4Y-TZP zirconia. Conclusions Shortening the sintering time may lead to differences within clinically acceptable limits. The manufacturer's recommendations according to material composition should be implemented with care.